Earth leakage tripping? Causes, safe checks and repairs
An earth leakage that keeps tripping means current is escaping where it should not. Here is what usually causes it, how to narrow it down safely, and when to call an electrician in Pretoria East.
What the earth leakage actually does
The earth leakage unit in your DB board (also called an RCD) compares the current going out on the live wire with the current coming back on the neutral. If some of it leaks away, through damp, damaged insulation or a person, it switches off in a fraction of a second.
In homes it is normally rated to trip at 30 mA, low enough to protect people from a dangerous shock. So when it trips, it is doing its job. The question is where the leak is.
Never bypass the earth leakage or have it swapped for a less sensitive one to stop the tripping. It is the device that protects your family from electric shock.
The most common causes
Water and damp
Garden lights, outside plugs, flood lights, pool lights and cable joints that let water in. The classic sign is tripping after rain or overnight.
A faulty appliance
Kettles, washing machines, dishwashers, fridges, heaters and air fryers. When an element or motor starts breaking down, it leaks current to earth.
The geyser
A failing geyser element is one of the most common causes. It often trips the earth leakage as soon as the geyser switches on.
Pool pumps and motors
Pumps and motors outdoors get wet, wear out and their cables get damaged.
Damaged wiring
Rodents chewing cables in the roof, a nail or screw through a cable, a garden cable cut by a spade, or old insulation breaking down.
The unit itself
Earth leakage units can fail with age. Many appliances on one unit can also add up to enough small leakage to trip it.
Why it trips at night or when it rains
At night
Something switches on: outdoor lights on a day/night sensor, a geyser or pool pump on a timer. Dew also settles on outdoor fittings in the early hours. Note the time it trips.
When it rains
Water finds its way into outdoor lights, plugs, junction boxes and cable joints. Summer thunderstorms bring both heavy rain and lightning, so tripping often starts in the storm season.
How to find the cause safely
You can usually narrow it down to one appliance or one circuit yourself. Only do this if there is no burning smell, smoke or water at the DB board.
- Unplug everything. Every appliance in every plug, not only switched off at the wall.
- Reset the earth leakage. If it stays up, plug appliances back in one at a time, waiting a minute or two between each. When it trips, you have found the likely culprit. Leave that appliance unplugged and have it checked.
- Still tripping with everything unplugged? Switch off all the circuit breakers, reset the earth leakage, then switch the breakers back on one at a time. The breaker that makes it trip is the circuit with the fault. Leave that breaker off.
- Remember hard-wired equipment. The geyser, pool pump and gate motor cannot be unplugged, so the breaker test in step 3 is how you find a fault on them.
- Trips with all breakers off, or will not reset at all? The fault is in the board, the main supply cable or the earth leakage unit itself. Call an electrician.
Do
- Write down when it trips and what had just switched on.
- Leave a faulty circuit or appliance off until it is repaired.
Do not
- Bypass, tape up or replace the earth leakage yourself.
- Open the DB board or keep resetting a unit that keeps tripping.
When to call us
Call us if you have found the circuit but not the fault, if it trips with everything off, if the geyser is the problem, or if it trips now and then and you cannot pin it down. That is where our fault-finding equipment earns its keep.
We test the insulation on the circuits and equipment to find exactly where the current is leaking, repair it and check that the earth leakage trips as it should. You get your power back and your protection still works.
- 24-hour emergency call-outs in Pretoria East
- Same-day service for emergencies
- Free expert advice on the phone
Earth leakage questions
Why does my earth leakage trip when it rains?
Water is getting into something outdoors: a garden light, an outside plug, a flood light, a pool light or a cable joint. Damp completes a path to earth and the earth leakage switches off. Find the circuit with the breaker test, leave it off and have the outdoor fittings checked and sealed.
Why does my earth leakage trip at night?
Usually because something switches on at night: outdoor lights on a day/night sensor, a geyser or pool pump on a timer, or dew settling on outdoor fittings. Note the time it trips; it is a useful clue for the electrician.
Can a geyser trip the earth leakage?
Yes, and it is one of the most common causes. When a geyser element starts to fail it leaks current to earth, often tripping the earth leakage as soon as the geyser switches on. Switch off the geyser breaker; if the earth leakage then stays up, the geyser circuit is the likely cause.
Can an appliance trip the earth leakage even when it is switched off?
Sometimes, yes. That is why you should unplug appliances, not only switch them off at the wall, when you are trying to find the cause.
Is it safe to keep resetting the earth leakage?
No. Resetting it once to see if it holds is fine. If it trips again, something is leaking current, and repeated resets do not fix that. Never bypass it.
Can I replace the earth leakage unit myself?
No. Work inside the DB board must be done by a licensed electrician, and changes to the board affect your Certificate of Compliance.
Earth leakage will not stay up?
Call us and we will find the leak with proper testing. Pretoria East and Centurion, 24-hour emergency call-outs.